国产一级淫一区二区波多野结衣_日韩无码免费一级片_国产日韩欧美主播视频在线播放_乱伦无码免费综合_成全视频高清免费观看_国产三级成人第一_久久亚洲aⅴ永久无码精品_电影免费在线观看日本_人妻内谢精中文字幕_天堂亚洲欧美在线中文

Contact Us

Explosion Inflatable Air Blower installation inspection

Date: 2015-3-31   Click: 1391 Times

Explosion "Inflatable Air Blower" First check the frame, without deformation blades, blade rotation is flexible, with or without friction phenomenon. Check all fasteners are complete, tighten, there should be proof certificate number. Check motor with 500V megger insulation resistance, the resistance value if less than 50MΩ, the short-circuit current application and drying method or drying method, so that "Inflatable Air Blower" insulation resistance greater than 5 MΩ. Connect the power cable diameter should be consistent with the ring, tighten the compression nut should ensure that after the cable between the seals, no gap between the nozzle outlet, otherwise it will lose the proof performance. The assembly should ensure proof gap is less than 0.2mm, replace "Inflatable Air Blower" bearing grease, grease grades for its ZG-2H complex calcium-based Run. When installing, note flameproof surface, when the surface to be coated assembly explosion 204-1 antirust grease. All proof surface may not have damage or corrosion, or they will lose the proof performance, if any damage or corrosion phenomenon according to the "explosion-proof electrical equipment surface defect treatment provisions" repair.

Back to: Industry news

+86-0769-83660708